China's Refractories

《中国耐火材料》英文版

• Original article • Previous Articles     Next Articles

Cooling Water Flow Rate Calculation for Hearth of Large Blast Furnaces

LI Hengxu, CHE Yuman, ZHOU Zhe, WANG Qi, WANG Hongtao   

  1. Angang Steel Company Limited, Anshan 114021, China
  • Published:2015-06-17

Abstract: The cooling water flow rate for hearth of large blast furnaces was calculated by simulation. The results show that the cooling water flow rate shall be above 4 200 m3/h for hearth of large blast furnaces; to meet requirements of the increasing smelting intensity and to ensure the safety at the end of the first campaign, the designed maximum cooling water flow rate should be 5 900 m3/h; according to the flow distribution stability and the calculated resistance loss, hearth cooling stave pipes with the specification of Ф76 mm×6 mm shall be adopted to assure the flow velocity in pipes of hearth cooling stave in the range of 1.9-2.3 m/s.

Key words: hearth of blast furnaces, cooling water flow rate, simulation calculation